Module A-149-1 is the first module of the A-149-x range. In this group we present by popular request several functions of Don Buchla’s “Source of Uncertainty 265/266” (SOU) modules that cannot be realized with existing A-100 modules. Many functions of Buchla’s 265 and 266 SOU can be realized with existing A-100 modules. For details please refer to A-100 patch examples.
Module A-149-1 has available four different analog random control voltages that are generated in different ways.
The “Quantized Random Voltages” section has available 2 CV outputs: “N+1 states” and “2N states”. N is an integer number in the range 1…6 that can be adjusted with the manual control (Man N) and an external control voltage CVN with attenuator. Whenever the rising edge of the input clock signal (Clk In) appears a new random voltage is generated at the N+1 resp. 2N output. The N+1 output is capable to generate N+1 different voltage levels (or states), the 2N output up to 2N different states. If for example N is set to 4 the N+1 output generates up to 5, the 2N output 16 different states. The voltage steps of the 2N output are adjusted to 1/12 V in the factory. Consequently exact semitones can be obtained in combination with a VCO. The voltage steps of the n+1 output are adjusted to 1.0 V in the factory corresponding to octave intervals in combination with a VCO. For each output a trimming potentiometer is available on the pc board that enables the user to select other voltage steps for the output in question.
Even the “Stored Random Voltages” section has 2 stepped CV outputs available: one with even voltage distribution of the max. 256 output states and second one with adjustable voltage distribution probability. The distribution probability is adjusted by a manual control (Man D) and an external control voltage CVD with attenuator. With the control set fully counterclockwise most of the random voltages will be low magnitude but even medium and high magnitude voltages may appear but with smaller probability. As the control is turned to the right (or a positive control voltage appears at the CVD input) the distribution moves through medium to high magnitude voltage probability. The symbol at the lower jack socket shows this coherence graphically. The voltage range is 0…+5V for both outputs of the “Stored Random Voltages” section. For each output a trimming potentiometer is available on the pc board that enables the user to select another voltage range for the output in question.
The A-149-1 can be extended by 8 random digital voltages with the A-149-2 Digital Random Voltages module.
Technical Specs.:
- Width: 12HP
- Depth: 60mm
- Current Draw: 40mA